Use for periodic maintenance (holiday seal) for burns or removing foreign matter
-
1
End product processing
It is not necessary to change the processing temperature of the leading resin if it is within the operating temperature range of the Z CLEAN™ being used.
- 2
Loading, Cleaning and Replacing Z CLEAN™
Clean until Z CLEAN™ changes from the leading resin color to milky-white, then replace.
- 3
Stopped with Z CLEAN™ Filled
Do not empty the Z CLEAN™ in the hopper to prevent oxygen getting into the cylinder.
- 4
Heater power off
- 5
Holiday Seal
- 6
Heater power on
- 7
Drain Z CLEAN™ in the molding machine.
Check that the Z CLEAN™ inside the molding machine has plasticized.
- 8
Loading subsequent resin
Set to the processing temperature of the subsequent resin.
- 9
Replace the subsequent resin
Replace until Z CLEAN™ is switched to subsequent resin.
- 10
Molding and confirmation
- 11
Start product processing
Effective "holiday seal" for removal of burn or foreign matter
By filling the molding machine with Z CLEAN™ for about one to two days, the ingredients contained in Z CLEAN™ will penetrate and clean the burn or foreign matter. Periodic "holiday seal" can greatly reduce the need for disassembly and cleaning of molding machines, and improve yield and production efficiency.
- 2