Use for periodic maintenance (holiday seal) for burns or removing foreign matter

  1. 1

    End product processing

    It is not necessary to change the processing temperature of the leading resin if it is within the operating temperature range of the Z CLEAN™ being used.

  2. 2

    Loading, Cleaning and Replacing Z CLEAN™

    Clean until Z CLEAN™ changes from the leading resin color to milky-white, then replace.

  3. 3

    Stopped with Z CLEAN™ Filled

    Do not empty the Z CLEAN™ in the hopper to prevent oxygen getting into the cylinder.

  4. 4

    Heater power off

  5. 5

    Holiday Seal

  6. 6

    Heater power on

  7. 7

    Drain Z CLEAN™ in the molding machine.

    Check that the Z CLEAN™ inside the molding machine has plasticized.

  8. 8

    Loading subsequent resin

    Set to the processing temperature of the subsequent resin.

  9. 9

    Replace the subsequent resin

    Replace until Z CLEAN™ is switched to subsequent resin.

  10. 10

    Molding and confirmation

  11. 11

    Start product processing

Effective "holiday seal" for removal of burn or foreign matter

By filling the molding machine with Z CLEAN™ for about one to two days, the ingredients contained in Z CLEAN™ will penetrate and clean the burn or foreign matter. Periodic "holiday seal" can greatly reduce the need for disassembly and cleaning of molding machines, and improve yield and production efficiency.